ultrasonic-flowmeter-1.png

AUF610 Đại lý hãng Alia tại Việt Nam, nhà phân phối hãng Alia tại Việt Nam , thiết bị đo lưu lượng Alia, thiết bị đo mức Alia

AUF610series is a portable transit-time ultrasonic flowmeter with clamp-on transducers for non-invasive liquid measurement.
Based on microprocessor and programmable flow measurement techniques the process flow can be accurately measured without interrupting the flow and with low installation costs.

 

FEATURES
 


 4 line LCD to display flowrate, totalizer signal condition..etc  
 The flowmeter is designed in high accuracy +/-1.0%  
 Small sized (260 * 100 * 35mm) light-weight (600g)  
 Wide range, Velocities ( 0.01 ~ +/- 32 m/s)  
 Ni-MH Battery lasts for over 10 hours continuous operation  
 Maximum temperature 160 oC  
 Transducers for pipes size from 15 to 6000 mm (1/2" ~ 240")  
 Built-in magnet in transducers, no need for steady tool on metal pipe  
 Data logger which records flowrate, date, total flow, signal condition..etc  
 Response time less than 1 second  

 
SPECIFICATION
 
 

 

Measuring Principle: Keypad:
Transit time difference 18 Key with tactile action
Pipe Size: Response Time:
S Type : 15 mm ~ 100 mm (1/2" ~ 4") Less than 1 second
M Type : 50 mm ~ 1000 mm (2" ~ 40") Flow Velocity:
L Type : 300 mm ~ 6000 mm (12" ~ 240") 0.01 ~ +/- 32 m/s
HS Type : 15 mm ~ 100 mm (1/2" ~ 4") Resolution:
HM Type : 50 mm ~ 1000 mm (2" ~ 40") 0.0001 m/s
Pipe Material: Ambient Temperature:
Cast Iron, Stainless Steel, Ductile Iron
-40 ~ +60 oC
Copper, PVC, Aluminum, Asbestos Ambient Humidity:
Fiberglass... Etc 90% RH or Less
Liner Material: Built-in Battery:
Tar Epoxy, Rubber, Mortar, Polypropylene, Ni-MH Battery
Polystyrol, Polystyrene, Polyester, Ebonite, Operation Time:
Polyethylene, Teflon... etc > 10 Hours
Display: Charger:
4 Line LCD with illumination 90 ~ 260Vac 50/60 Hz, 8-12 Hr charging
Flowrate Data Storage:
5 digit with decimal point Operation parameters and totalizer 
Totalizer figures are stored by EEPROM for more
8 digit, Forward, Reverse & Net values than 10 years
Engineer Unit Data Logger:
M3, Liter, US Gallon, Imperial Gallon, Limitless overwriting in 64 columns
Million Gallon, Cubic Feet, US Barrels, (Flowrate, totalizer, time, date included)
Imperial Barrels, Oil Barrel Output:
Time Unit Pulse (Open collector)
Second, Minute, Hour, Day Alarm:
Other High/Low with buzzer
Velocity, Date, Time, Signal condition Power Consumption:
Accuracy: Less than 2W
+/- 1% ~ +/- 2% value of reading (0.5 ~ 30 m/s) Dimensions:
+/-0.5% value of reading (Online calibration) 260 * 100 * 35 mm
Repeatability: Weight:
+/-0.2% value of reading 0.6 Kg
  Protection Class:
  Converter
  IP65
  Sensor
  IP68 (Submersible)