AMC3100 Đại lý hãng Alia tại Việt Nam, nhà phân phối hãng Alia tại Việt Nam , thiết bị đo lưu lượng Alia, thiết bị đo mức Alia
The Aliamag AMC3100 series converter is a microprocessor based intelligent transmitter that can be paired with any of the Alia AMF series sensors. The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting.
FEATURES |
|
Three line LCD display Flow Rate / Totalizer
Accuracy of +/-0.2% value of reading
Bi-directional flow measurement, current and pulse output
Explosion Proof, Exd(ib)ibqllBT5
Records up to 99 power on / off time
MODBUS/HART communication
|
|
SPECIFICATION |
|
Excitation: |
Keypad: |
DC pulsed |
3 internal keys for programming |
Display: |
and display control |
3 lines LCD with illumination |
Remote switch instead, no need to open |
Line 1 |
cover |
11 digit totalizer for forward flow |
Low Flow Cutoff: |
11 digit totalizer for reverse flow |
0 to 9.9 % |
11 digit totalizer for difference |
Data logger Function: |
Line 2 |
99 times flowrate records for power on/off |
5 digit flowrate / velocity / % / mA / HZ |
Record Data: |
Line 3 |
Date/Time when Power on/off |
Parameter / Query / Clr tot / Query LOG |
Flow rate when Power on/off |
Alarm, Guidance |
Totalizer when Power on/off |
Unit |
Damping: |
M3/H, L/H, Kg/H, T/H, L/min, M3/min, GPH |
0 to 99 Seconds |
GPM, ML/H, ML/m, ML/sec |
Density Setting: |
Measuring Range: |
0.1 to 9.99 g/cm3 |
Min. 0 to 0.15 m/s |
Self Diagnosis: |
Max. 0 to 15 m/s |
The following error message are |
Accuracy: |
displayed if failure occurs |
+/-0.2% read-out values (Velocity >=0.5 m/s) |
- Coil failure |
+/-0.001 m/s (Velocity < 0.5 m/s) |
- Power failure |
Repeatability: |
- Overanged Output |
+/-0.05% read-out values |
- Internal error |
Current Output: |
- Overflow |
4-20 mA (Isolated) |
- Empty pipe |
Load |
Cable Entry: |
Max. 600 |
Standard :M20 / PG11 Option:1/2"NPTF |
Pulse output: |
Protection Class: |
Open collector |
IP 67, Explosion proof, Exd(ib)ibqllBT5 |
Rating |
Ambient Temperature: |
3 to 30 Vdc, 20 mA Max. |
|
Pulse Rate: |
Material: |
1)Scale pulse (Pusle/M3, Pulse/L, Other) |
Aluminum Alloy |
2)Frequency: 0-5000 Hz |
Power Supply: |
Pulse Width: |
90-260 Vac, 50/60 Hz |
50% of band width |
24Vdc +/-10% (Option) |
Alarm: |
Power Consumption: |
High/Low with open collector output |
3-17 W (Dependent on sensor size) |
Rating |
Weight: |
3 to 30 Vdc, 20 mA Max. |
4.5 Kg |
Communication: |
Mounting: |
RS 485 (MODBUS Protocol) |
Wall mounting |
HART signal (Compatible) |
Bracket on 2" pipe |
Data Storage: |
|
Operation parameters and totalizer |
|
figures are stored by EEPROM for more |
|
than 10 years |
|
|
|
|
|