AFC365 Series Flow Computer is a microprocessor-based instrument designed to measure compensated flow in industrial environment.
The AFC365 incorporates the Ideal Gas / Steam / Natural Gas compensation.
The Backlit LCD display simplifies programming and clearly indicates all parameters as well as engineering units.
AFC365 Đại lý hãng Alia tại Việt Nam, nhà phân phối hãng Alia tại Việt Nam , thiết bị đo lưu lượng Alia, thiết bị đo mức Alia
FEATURES |
|
DIN Size (96mm*96mm), 320*240 Pixels, 4-line LCD display
Built-in 8MB memory, applicable to long-term data record
Common input signal: mA, RTD, Frequency etc.
High Accuracy +/-0.1% of Reading
4-20mA / Relay / RS485 output
Ideal Gas/ General Gas / Steam / Energy formula
24VDC Aux. power supply available for 2 wires system
Fascia Sealing for IP65(NEMA 4X) water tight
Hourly / Daily / Monthly / Yearly history data record
|
|
SPECIFICATION |
|
Number of Inputs: |
Display: |
3 Channels |
3.5" Mono-screen LCD with Backlit |
Flow Function: |
Response Time: |
Input |
100 ms |
4-20 mA / Frequency (0-10 KHz) |
Keypad: |
Display |
6 keys for programming and display |
5 digits flowrate with decimal point |
control |
13 digits totalizer with decimal point |
Engineer Unit: |
Accuracy |
21 different engineering units |
+/-0.1% of reading |
Parameter Protection: |
Temperature Function: |
2 Password entries (6 Digits) for |
one or two point (Energy calculator) |
Supplier and User |
Input: |
Logging Rate: |
PT100 / 4-20 mA |
1 minutes ~ 60 minutes Per Data |
Display |
Recording Capability: |
4 digits temperature value with decimal point |
30 days (1 Data/minutes) |
Accuracy |
1800 days (1 Data/Hour) |
+/-0.1 oC |
Storage Memory: |
Pressure Function: |
8 MB (on board) |
Input |
Recycling Mode: |
4-20 mA |
Newest data overwrites oldest data |
Display |
Protection Class: |
5 digits pressure value with decimal point |
NEMA4 / IP65 (Fascia sealing) |
Accuracy |
Weight: |
+/-0.1% of reading |
0.5 Kg Maximum |
Calculation Function: |
Dimensions: |
Ideal Gas, Temperature & Pressure Comp. |
96mm (W) * 96 mm (H) *150 mm (D) |
General Gases, Temp & Pressure Comp. |
Ambient Temperature: |
Natural Gas, NX-192 Formula |
-10 ~ +60 oC |
Saturated Steam, Superheated Steam |
Ambient Humidity: |
Liquid Mass, Density calculation |
10% ~ 85%RH (5 ~ 40 oC) |
Alarm Types: |
Power Supply: |
High & Low alarm, Incr. & Decr. alarm |
85-260VAC, 50/60Hz |
Aux. Power Output: |
Vibration Test: |
12VDC / 24VDC,100mA for Flow Transmitter |
10~60Hz ,10 m/S2 for 3 hours |
24VDC, 100mA for Temperature Transmitter |
Power Consumption: |
24VDC ,100mA for Pressure Transmitter |
<=10 W |
Output: |
Communication: |
4-20 mA, Load 750 * 1 point |
RS485 (MODBUS Protocol) |
Relay, 3A/250V * 1 point |
Parameter Storage: |
|
Operation parameters are stored by |
|
EEPROM for more than 10 years |
|
|