AFC365 Series Flow Computer is a microprocessor-based instrument designed to measure compensated flow in industrial environment.
The AFC365 incorporates the Ideal Gas / Steam / Natural Gas compensation.
The Backlit LCD display simplifies programming and clearly indicates all parameters as well as engineering units.

AFC365 Đại lý hãng Alia tại Việt Nam, nhà phân phối hãng Alia tại Việt Nam , thiết bị đo lưu lượng Alia, thiết bị đo mức Alia

FEATURES
 


 DIN Size (96mm*96mm), 320*240 Pixels, 4-line LCD display
 Built-in 8MB memory, applicable to long-term data record
 Common input signal: mA, RTD, Frequency etc.
 High Accuracy +/-0.1% of Reading
 4-20mA / Relay / RS485 output
 Ideal Gas/ General Gas / Steam / Energy formula
 24VDC Aux. power supply available for 2 wires system
 Fascia Sealing for IP65(NEMA 4X) water tight
 Hourly / Daily / Monthly / Yearly history data record

 
SPECIFICATION
 
 
Number of Inputs: Display:
3 Channels 3.5" Mono-screen LCD with Backlit
Flow Function: Response Time:
Input 100 ms
4-20 mA / Frequency (0-10 KHz) Keypad:
Display 6 keys for programming and display
5 digits flowrate with decimal point control
13 digits totalizer with decimal point Engineer Unit:
Accuracy 21 different engineering units
+/-0.1% of reading Parameter Protection:
Temperature Function: 2 Password entries (6 Digits) for
one or two point (Energy calculator) Supplier and User
Input: Logging Rate:
PT100 / 4-20 mA 1 minutes ~ 60 minutes Per Data
Display Recording Capability:
4 digits temperature value with decimal point 30 days (1 Data/minutes)
Accuracy 1800 days (1 Data/Hour)
+/-0.1 oC Storage Memory:
Pressure Function: 8 MB (on board)
Input Recycling Mode:
4-20 mA  Newest data overwrites oldest data
Display Protection Class:
5 digits pressure value with decimal point NEMA4 / IP65 (Fascia sealing)
Accuracy Weight:
+/-0.1% of reading 0.5 Kg Maximum
Calculation Function: Dimensions:
Ideal Gas, Temperature & Pressure Comp. 96mm (W) * 96 mm (H) *150 mm (D)
General Gases, Temp & Pressure Comp. Ambient Temperature:
Natural Gas, NX-192  Formula -10 ~ +60  oC
Saturated Steam, Superheated Steam Ambient Humidity:
Liquid Mass, Density calculation 10% ~ 85%RH (5 ~ 40  oC)
Alarm Types: Power Supply:
High & Low alarm, Incr. & Decr. alarm 85-260VAC, 50/60Hz
Aux. Power Output: Vibration Test:
12VDC / 24VDC,100mA for Flow Transmitter 10~60Hz ,10 m/S2  for 3 hours
24VDC, 100mA for Temperature Transmitter Power Consumption:
24VDC ,100mA for Pressure Transmitter <=10 W
Output: Communication:
4-20 mA, Load 750   * 1 point RS485 (MODBUS Protocol)
Relay, 3A/250V * 1 point Parameter Storage:
  Operation parameters are stored by 
  EEPROM for more than 10 years